Safety instructions

2.2

Device and application-specific safety instructions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2.2

Device and application-specific safety instructions

• During operation, the communication module must be securely connected to the standard

device.

• With external voltage supply, always use a separate power supply unit, safely separated to EN

61800-5-1 in every control cabinet (SELV/PELV).

• A safety bus system (PROFIsafe) can only be operated via the upper module slot (MXI1) of the

Servo Drive 9400.

• Only use cables corresponding to the given specifications.

Ethernet cable specification

( 29)

2.3

Residual hazards

Protection of persons
If Servo Drives 9400 are used on a phase earthed mains with a rated mains voltage  400 V,

protection against accidental contact is not guaranteed without external measures.

Protective insulation

( 18)

Device protection
The communication module contains electronic components which may be damaged or destroyed

by electrostatic discharge.

Installation

( 22)

Documentation for the standard device, control system, system/machine
All the other measures prescribed in this documentation must also be implemented.

Observe the safety instructions and application notes contained in this manual.