11. Trouble Shooting Guide

11.1 System Diagnostics

Your DLC contains extensive diagnostics that allow it to determine the source of common problems. If
your DLC is not operating properly, your first course of action should be to review the {DIAGNOSTICS}
sub-menu. To access this menu from the standard operating mode follow this procedure (provided your
user interface – keypad and display – is functioning):

1. Press [MOTOR] repeatedly until the display reads {MOTOR OFF}.

2. Cycle power to the DLC (turn the main OFF then ON). This will cause the self-test routine to re-

execute.

3. Press [MENU]. The screen {–MENU– / DIAGNOSTICS-1} is displayed. The value, in this case

'1' indicates how many failures were detected.

4. Press [ENTER] to enter the Diagnostics Menu. The screen {DIAG MENU 1/11 / POWER IN:

OK} is displayed.

5. Repeatedly press [UP] to cycle through all nine Diagnostic screens.

6. If a screen displays a FAIL message, press [ENTER] to display the time and date the failure

occurred. Press [ENTER] again to display the clear screen. Press [UP] and then [ENTER] to clear
the message. (This paragraph does not apply should you encounter a Battery Fail or Circuit Fail
situation).

Make a note of any failures reported in the Diagnostics Menu. Using this information, proceed with
the troubleshooting instructions below:


Other actions may be necessary to bring the process back to normal conditions before clearing a
failure.

MENU (DIAGNOSTICS)

Symptom

Probable Cause

Possible Solution

DIAG 1/11
POWER IN:
FAIL

The power to the DLC failed while the pump
motor was running.

Place DLC in {MOTOR OFF} operating
mode before disconnecting power. Refer to
POWER trouble shooting.

DIAG 2/11
ANALOG IN:
FAIL

The Analog Input signal fell under the
calibrated range, or fell to 0 within 0.25
seconds (i.e., the signal was changing by
more than 8.8mA per second and was less
than 0.3mA).

Place DLC in {MANUAL MODE} or OFF
before the signal loss occurs. Re-calibrate
Analog Input. Condition Analog Input
Signal. Refer to ANALOG INPUT trouble
shooting
.

DIAG 3/11
MODBUS
FAIL

A properly formatted and addressed
MODBUS message was not received in the
allotted time.

Increase the Response Time setting.

DIAG 4/11
LEAK DET:
FAIL

The Leak Detection Switch closure activated
according to its configuration.

Review Section 7-General Operation: Leak
Detection Failure Set-up
. Refer to LEAK
DETECTION trouble shooting
.

DIAG 5/11
LEVEL
INPUT: FAIL

The Level Input Switch closure activated
according to its configuration.

Review Section 7-General Operation:
Level Input Failure Set-up. Refer to
LEVEL INPUT trouble shooting.

DIAG 6/11
MOTOR TEMP

The motor exceeded its maximum internal
temperature.

Relocate to a cooler area.