3 units – Pulsafeeder Pulsar DLC User Manual

Page 73

background image

68

Press [UP] to change the value to {YES}. Press [ENTER] to accept your selection. The following
message is displayed:

PLEASE WAIT

5. The first screen displayed during the Re-Set procedure prompts you to turn the motor on.

TURN MOTOR ON

TESTING ENCODER

6. Press [MOTOR].

You will hear the pump motor spin up, and the DLC will perform an Encoder test (displaying the
following message:)

PLEASE WAIT

TESTING ENCODER

When the Encoder test is complete, (usually takes about 2 or 3 seconds) the DLC performs a Zero
Calibration (displaying the following message:)

PLEASE WAIT

CALIBRATING ZERO

When the Zero Calibration is complete, you are returned to the {–MENU– / FACTORY DEFAULTS}
screen.

Press [MENU] and the next screen displayed is:

MOTOR STOPPED

Re-establish any Menu and Calibration settings that are non-standard at this time..

7.3

Units

By pressing [UNITS] with the motor on, the display will scroll through the CMH, GPH, LPH, CCH,
CMM, GPM, LPM, CCM, % flow, % stroke length or % motor speed. The DLC will automatically
convert the motor and stroke settings based on the calibrated flow, to the above referenced units.

If the {MENU / NUMBER FORMAT} was setup to show only one specific calibrated unit of flow, then
you will have only that unit displayed alternately with the % flow display.

The accuracy of the flow rate display is dependent on the pump flow calibration accuracy.