2 pulsar motor – Pulsafeeder Pulsar DLC User Manual
Page 16

11
5.4.2 PULSAR Motor
Connect the pump motor to the J3 terminal block labeled 'PUMP MOTOR OUT AC/DC.' (Use 14
AWG (2.1mm
2
), 105
ø
C insulation wire size or larger.) The pump motor must be wired to operate at
the DLC supply voltage (i.e., if the power supplied to J1 is 115VAC 60Hz, then the motor must operate
on 115VAC at 60Hz).
T
HE
DLC
USES SOLID
-
STATE RELAYS FOR IT
'
S HIGH VOLTAGE OUTPUTS
(
I
.
E
.,
MOTOR AND
ALARM
). I
N THE
'OFF'
STATE
,
THESE DEVICES TYPICALLY LEAK
20-30
M
A
OF CURRENT AT THE
SUPPLY VOLTAGE TO THE ATTACHED DEVICE
(
OR TERMINAL BLOCK
)! T
HE SUPPLY POWER
MUST BE DISCONNECTED AT THE MAIN BEFORE WORKING ON ELECTRICAL CONNECTIONS OR
ANY MOVING PUMP COMPONENTS
(
E
.
G
.,
MOTOR
,
GEAR TRAIN
,
ETC
.).
D
OUBLE CHECK ALL CONNECTIONS TO CONFIRM GOOD ELECTRICAL CONTACT BETWEEN THE
TERMINAL BLOCK CLAMP AND BARE WIRE
. M
AKE SURE THE CLAMP IS ON THE WIRE
,
NOT THE
INSULATION
. I
NSURE THAT BARE WIRE IS NOT FRAYED AND DOES NOT RISE ABOVE DIVIDERS
.
If the PULSAR pump motor is controlled by a Variable Speed Drive (e.g., DC Drive), the Variable
Speed Drive must be powered by the DLC. Wire the Variable Speed Drive to J3. Wire the PULSAR
motor to the Variable Speed Drive in accordance with the Variable Speed Drive manufacturer's
instructions. Refer to Section 8 – Diagrams: Diagram 2 for recommended wiring.
If the PULSAR pump motor or Variable Speed Drive operates at a voltage different than that supplied
to the DLC or is a three-phase motor, then a motor starter must be used. Wire the motor starter relay to
J3. Wire the PULSAR motor or Variable Speed Drive to the motor starter in accordance with the
starter manufacturer's instructions. Refer to Section 8 – Diagrams: Diagram 2 for recommended
wiring.
D
AMAGE MAY OCCUR TO THE
DLC
IF THE
PULSAR
PUMP MOTOR IS NOT WIRED AND
COMMUNICATING WITH THE
DLC.