14.5 Coils
Coils are discrete, single bit outputs like the ALARM OUTPUT and DIGITAL OUTPUT.
Notes:
•
Read only.
•
The coil information is packed as 8 coils per byte.
•
Coils are accessible through Function Code 0x01.
•
The requested value is returned in the least most significant bit.
Function
Address
DDE Ref.
Purpose
Data Format
Read (0x01)
0x0000
000001
Alarm Output
Bit(0x01 = On)
Read (0x01)
0x0001
000002
Digital Output
Bit(0x01 = On)
14.6 Input Bits (1x references)
Input Bits are discrete, single bit inputs such as the keyboard KEYS, LEAK DETECTION, LEVEL
INPUT and THERMOSTAT inputs.
Notes:
•
Read only.
•
The input information is packed as 8 input bits per message byte.
•
Input Bits are accessible through Function Code 0x02.
•
The requested value is returned in the least significant bit.
Function
Address DDE Ref.
Purpose
Data Format
READ (0x02)
0x0000
100001
Key Pad Input: START/STOP
Bit(0x01=On)
READ (0x02)
0x0001
100002
Key Pad Input: BATCH
Bit(0x01=On)
READ (0x02)
0x0002
100003
Key Pad Input: UP
Bit(0x01=On)
READ (0x02)
0x0003
100004
Key Pad Input: MENU
Bit(0x01=On)
READ (0x02)
0x0004
100005
Key Pad Input: CALIBRATE
Bit(0x01=On)
READ (0x02)
0x0005
100006
Key Pad Input: DOWN
Bit(0x01=On)
READ (0x02)
0x0006
100007
Key Pad Input: UNITS
Bit(0x01=On)
READ (0x02)
0x0007
100008
Key Pad Input: MODE
Bit(0x01=On)
READ (0x02)
0x0008
100009
Key Pad Input: ENTER
Bit(0x01=On)
READ (0x02)
0x0009
100010
Digital Input: LEAK DETECT
(J4-3, J4-4)
Bit(0x01=On)
READ (0x02)
0x000A
100011
Digital Input: LEVEL INPUT
(J4-5, J4-6)
Bit(0x01=On)
READ (0x02)
0x000B
100012
Digital Input: MOTOR
THERMOSTAT (J10-3, J10-4)
Bit(0x01=On)
READ (0x02)
0x000C
100013
Encoder: Channel B
Bit(0x01=On)
READ (0x02)
0x000D
100014
Encoder: Channel A
Bit(0x01=On)
READ (0x02)
0x000E
100015
Digital Input: Tachometer
(J10-1, J10-2)