beautypg.com

16 number format – Pulsafeeder Pulsar DLC User Manual

Page 66

background image

61

7. If the pin number is not correct or you don’t want the selected security level, press [UP] to change the

display to {CONFIRM CHANGE? / NO}

CONFIRM CHANGE?

NO

Press [ENTER] to reject the security changes.

8. The menu display returns to {–MENU– / SECURITY} screen.


Remembering the PIN # you set, is probably one of the most important functions of setting security.

7.2.16 Number Format

Accessing {–MENU – / NUMBER FORMAT} allows the modification of three system variables:

a) The meaning of the comma and decimal point can be interchanged between English and European

format (step 2).

b) Change the decimal position (step 3).

c) Change the preferred unit of flow to be displayed when the [UNITS] key is pressed (step 4).

v

Number Format Set Up Procedure

1. Press [MENU]. Press [UP] or [DOWN] until the display reads {–MENU– / NUMBER FORMAT}.

Press [ENTER] to continue into the number format sub-menu.

2. The display shows the English numerical format of 9,999.99. Press [UP] to change to the European

format of 9.999,99.

e.g.: 9,999.99

DECIMAL OR COMMA

Press

[UP]

e.g.: 9.999,99

DECIMAL OR COMMA

Press [ENTER] to accept the displayed format.

3. The decimal position screen is displayed. Press [DOWN] to move the decimal position one place to the

left. Press [UP] to move the decimal position one place to the right. For example, the screen displays
9.99999, pressing [DOWN] causes the display to change to 0.999999. The valid range is 999.999 to
0.0999999.

Refer to the table in Section 10 – Factory Defaults for factory decimal position settings.


e.g.: 9.99999

DECIMAL POSITION

Press

[DOWN]

e.g.: 0.999999

DECIMAL POSITION

Press [ENTER] to accept the decimal position.

You should perform a pump flow calibration if you change the decimal position.

4. The Display Units screen is displayed.

ALL

DISPLAY UNITS

5. To accept the default setting of ALL, press [ENTER].

6. To specify the desired Display Unit, press [UP] or [DOWN] to cycle through the units options: CMH,

GPH, LPH, CCH. CMM, GPM, LPM, and CCM, until the desired unit is displayed.

Press [ENTER] to accept your selection.

7. The display returns to {–MENU– / NUMBER FORMAT} screen.