Low Voltage Outputs
Outputs
Field Wiring
Location
Specification / Description
Analog Output Channel
J5 Pin 1 is +
J5 Pin 2 is –
Any signal within the range of 0 – 20mA (e.g.: 4-20).
Minimum span of 2mA.
Maximum load: 700 ohms.
Reverse Acting standard on all units, which is accessible via calibration.
Fused at 50mA protected against mis-wiring.
Surge Protection: 7.4 Joules
Isolation: 500 volts from all inputs and outputs.
Alarm Status
J5 Pin 3 is +
J5 Pin 4 is –
Dry Contact (Transistor Type)
VCE (SAT): 0.3 volts
Max forward current: 50mA
Maximum 32VDC
On-state resistance: 100 ohms
Isolation: 5000 volts from all inputs, outputs and ground.
Follows the state of High Voltage Alarm Output, which may be software
configured as Normally Open or Normally Closed.
Digital Output
Programmable as
Remote Run Status
Or
Stroke Counter
Or
Mode Indication
J5 Pin 5 is +
J5 Pin 6 is –
Dry Contact (Transistor Type)
VCE (SAT): 0.3 volts
Max forward current: 50mA
Maximum 32VDC
On-state resistance: 100 ohms
Isolation: 5000 volts from all inputs, outputs and ground.
May be software configured as Normally Open or Normally Closed.
(Remote Run Status and Mode Indication only).