5.10 Fuse Replacement
Although Fuse replacement is not a part of normal installation, it is possible that fuse failure will result
from improper wiring. The DLC uses a total of 7 user replaceable fuses: 1 for the alarm relay output, 2
for each of the Current Input and Output Channels. The table below details fuse replacement information:
Designator
Function
Rating
Wickman P/N
Pulsafeeder P/N
F1
Alarm Relay
1A @ 250VAC
WK4048-ND
NP5300026-000
F2-7
Current I/O
50mA @ 250VAC
WK3022-ND
NP5300027-000
Replacement Fuse Information
Figure 11 details the location of these fuses on the Field Wiring Board.
Figure 11. – Fuse Location.
The Internal DLC power supply is fused at 2 Amps. This fuse is not user serviceable. The DLC Stroke
Length Adjustment Synchronous Motor is inherently protected. It can operate continuously in a locked
rotor state. The DLC also monitors this motor's duty cycle to maintain a 50% balance between ON and
OFF times. The serial ports and the Remote Run Status Output are protected by self-resetting current
limit devices. These components are not user serviceable.