Fan Modules
The AT-CVFAN module, as shown in Figure 10, is designed for use with
the AT-CV5000 chassis. You can install the same fan module in either fan
slot labeled A or B, located at the rear of the AT-CV5000 chassis. For
proper operation, two AT-CVFAN modules are preinstalled in the
AT-CV5000 chassis.
Caution
The AT-CVFAN modules are field-replaceable; however, they are
not hot-swappable. Therefore, make sure to power OFF the chassis
before replacing the fan modules.
Note
The AT-CV5000 chassis operates correctly even with one faulty fan
module. However, it will not operate correctly if one fan is missing
because this changes the air flow.
Figure 10. AT-CVFAN Module
Figure 11 illustrates the locations of the two fan modules at the rear of the
AT-CV5000 chassis.
Figure 11. Locations of Fan Slots A and B on an AT-CV5000 Rear Panel
To replace a fan module if one of the two AT-CVFAN modules failed, refer
to “Replacing an AT-CVFAN Module” on page 86.