Installing the AT-SBxPWRSYS1 AC System Power Supply

For background information on the AT-SBxPWRSYS1 Power Supply, refer
to “AT-SBxPWRSYS1 AC Power Supply” on page 53. The chassis must
have at least one AT-SBxPWRSYS1 Power Supply.

Warning
The electronic components in the AT-SBxPWRSYS1 Power Supply
can be damaged by electro-static discharges (ESD). Follow the
procedure in “Protecting Against Electrostatic Discharge (ESD)” on
page 90 t
o guard against ESD damage when unpacking and
installing the power supply.

To install the AT-SBxPWRSYS1 Power Supply, perform the following
procedure:

1. Choose a slot for the AT-SBxPWRSYS1 Power Supply in the chassis.

You may install it in either slot C and D, shown in Figure 46. The first
AT-SBxPWRSYS1 Power Supply should be installed in slot D,
because the slot does not have a blank power supply panel.

Figure 46. Power Supply Slots

Caution

The AT-SBxPWRSYS1 Power Supply will not work in slot A or B.

2. If the chassis already has a power supply in slot D, remove the blank

power supply panel from slot C by lifting the blank panel handle and
sliding it out of the slot, as shown in Figure 47 on page 92.

Slot A

AT-SBxPWRPOE1

Power Supply

Slot B

AT-SBxPWRPOE1

Power Supply

Slot C

AT-SBxPWRSYS1

Power Supply

Slot D

AT-SBxPWRSYS1

Power Supply