beautypg.com

Figure 117: removing the terminal screws – Allied Telesis SwitchBlade x8106 User Manual

Page 162

background image

Chapter 7: Powering On the Chassis

162

Figure 117. Removing the Terminal Screws

6. With a #3 Phillips-head screwdriver, connect the positive (+) power

lead wire to the positive terminal on the power supply, with one of the
terminal screws removed in the previous step. The positive terminal is
on the left. You may attach the terminals with the wires either above or
below the terminal block. Figure 118 on page 163 shows the positive
wire above the terminal block.

Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.