beautypg.com

Allied Telesis SwitchBlade x8106 User Manual

Page 212

background image

Chapter 10: Replacing Modules

212

Note

If the power wires are connected to the terminal block with the right
angle terminals, go to step 5.

4. Use a #1 screwdriver to loosen the two screws that secure the plastic

cover over the terminal block and slide the cover to the right. You may
need to slightly lift the locking handle to access the bottom screw.
Refer to Figure 143.

The plastic cover may not be present if the lead wires are connected to
the terminal block with the right angle terminals. If this is the case, you
may skip this step.

Figure 143. Opening the Plastic Window on the Terminal Block

5. Use a #3 screwdriver to remove the negative (-) lead wire from the

terminal block. The negative lead wire is on the right. Refer to Figure
144 on page 213.