Chapter 7: Powering On the Chassis

170

Figure 126. Connecting the Positive (+) Power Wire with a Right Angle

Terminal

7. With a #3 Phillips-head screwdriver, connect the negative (-) power

lead wire to the negative terminal on the power supply, with the
remaining terminal screw removed in step 5. The negative terminal is
on the right. Refer to Figure 127 on page 171.

Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.