Configuring Your System and Network

Alert Settings

3-8

SNMP/Network Management Settings

If you are using a Simple Network Management Protocol (SNMP) tool,
you can define the names of the servers to receive notification in case of a
failure.

To define the servers to receive notification:

1

Using the NetStorage web interface, click the Configuration tab, then
select Alert Settings > SNMP/Network Management.
By default, the Community String field is set to

public

and the Trap

Destination fields are blank.

2

In the Trap Destination fields, enter the IP addresses or names of the
servers you want the system to notify (up to five).

3

Enter a value in the Volume Capacity Threshold field to receive a
warning message if your volume gets to a certain capacity. By default,
the field is set to 95 percent

4

Click either:

Send SNMP Test Trap to send a cold boot test trap to the destination
addresses and save your changes.

Apply to only save your settings.

Note

The information on this screen is optional. Blank fields do not affect the
functionality of the device.