Power specifications – HP NetStorage 6000 User Manual
Page 161
System Specifications
Power Specifications
C-10
Power Specifications
MTBF (Mean Time Between any
Failure)
53,500 hours at 25oC, 10 Disk Drives
MTBCF (Mean Time Between
Critical Failure)
490,000 hours
MTTDL (Mean Time to Data Loss) Greater Than 1,000,000 hours
(RAID5 required)
Mean Life Requirement
35 Years
Availability
Better than 99.99%
a. Tests made while operating on the 120V range.
Specification
Description
Power Line
•
100V/120V/220V/240V +10%
•
50Hz and 60Hz +5%
Power Line Transient
•
Low Energy Pulse - 3KV / 100kHz Ring Wave
•
High Energy Pulse - 1KV at 1.2 Microsec by 50
Microsec
Recoverable Power
Line Surge
From 129V to 150V for 500 millisec
a
a. Tests made while operating on the 120V range.
Recoverable Power
Line Sag
From 108V to 80.5V for 500 millisec
Power Line Dropout
From lower limit to 0V for 10millisec -
Transparent to user
Power Availability
500 W maximum
Power Consumption
450 W typical, 10 HDDs installed
Specification
Description
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)