Troubleshooting and Error Codes
Determining Component Failure

E-7

Temperature out
of range

Check ambient temperature (must be
below 35° C).

Remove airflow restrictions at the front and
back faceplates.

Check fan status reported on front panel
and in NetStorage web interface.

Replace any failed system blowers, or call
an HP service representative if the CPU fan
has failed.

Network Activity Blinking red

All network links
are bad or
unattached

Check network cable and connections.

Check hub/switch port function and
protocol settings.

Drive Active (top
row of LEDs on
the front panel)

Off

Hard drive not
fully seated

Tighten the screw.

Blinking yellow

Drive initializing
or rebuilding

No action required.

Blinking red

Drive failure

Replace the drive. The drive replacement kit
provides detailed instructions.

LED

Light

Cause

Solution