HP NetStorage 6000 User Manual
Page 177
Troubleshooting and Error Codes
Hardware Error Codes
E-12
The power
supply X
temperature
is too high.
Power
supply xx in
the system
at location
yy is in
critical
condition:
the
temperature
is in a critical
range.
Power
supply xx in
the system
at location
yy is in
critical
condition:
the
temperature
is in a critical
range.
P22 Power
(X) overheat
Power module x -
temperature
warning.
Verify that the power
supply switch and master
power switch are both
turned on. Replace power
supply. The power supply
replacement kit provides
instructions.
The power
supply X has
no AC
power.
Power
supply xx in
the system
at location
yy is in
critical
condition:
the AC
power is not
detected.
Power
supply xx in
the system
at location
yy is in
critical
condition:
the AC
power is not
detected.
-
Power module x -
AC warning.
Check to insure that the
power supply is properly
secured in the unit.
Replace the power supply
if this is not effective.
NetStorage
6000 fan x
failed.
Fan xx in the
system at
location yy
failed.
-
-
-
Replace fan.
The primary
power cord
failed.
The primary
power cord
in the
system at
location yy
failed.
The primary
power cord
in the
system at
location yy
failed.
P31 Primary
power cord
failed
-
Re-establish good
connection with power
cord or replace power
cord.
The
secondary
power cord
failed.
The
secondary
power cord
in the
system at
location yy
failed.
The
secondary
power cord
in the
system at
location yy
failed.
P32
Secondary
power cord
failed
-
Re-establish good
connection with power
cord or replace power
cord.
Trap
Message
Event Log
Message
Message
LCD
Message
Web Interface
Message
Solution