beautypg.com

HP NetStorage 6000 User Manual

Page 177

background image

Troubleshooting and Error Codes

Hardware Error Codes

E-12

The power
supply X
temperature
is too high.

Power
supply xx in
the system
at location
yy is in
critical
condition:
the
temperature
is in a critical
range.

Power
supply xx in
the system
at location
yy is in
critical
condition:
the
temperature
is in a critical
range.

P22 Power
(X) overheat

Power module x -
temperature
warning.

Verify that the power
supply switch and master
power switch are both
turned on. Replace power
supply. The power supply
replacement kit provides
instructions.

The power
supply X has
no AC
power.

Power
supply xx in
the system
at location
yy is in
critical
condition:
the AC
power is not
detected.

Power
supply xx in
the system
at location
yy is in
critical
condition:
the AC
power is not
detected.

-

Power module x -
AC warning.

Check to insure that the
power supply is properly
secured in the unit.
Replace the power supply
if this is not effective.

NetStorage
6000 fan x
failed.

Fan xx in the
system at
location yy
failed.

-

-

-

Replace fan.

The primary
power cord
failed.

The primary
power cord
in the
system at
location yy
failed.

The primary
power cord
in the
system at
location yy
failed.

P31 Primary
power cord
failed

-

Re-establish good
connection with power
cord or replace power
cord.

The
secondary
power cord
failed.

The
secondary
power cord
in the
system at
location yy
failed.

The
secondary
power cord
in the
system at
location yy
failed.

P32
Secondary
power cord
failed

-

Re-establish good
connection with power
cord or replace power
cord.

Trap

Message

Event Log

Message

E-mail

Message

LCD

Message

Web Interface

Message

Solution