beautypg.com

HP StorageWorks 500 Modular Smart Array User Manual

Page 96

background image

Display Messages

C-4

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

31 I2C WRITE
FAILURE name>

Error

Read access has failed
to an internal device on
an I2C hardware bus.

Certain I2C devices are
considered critical and
will result in a failure of
the array controller while
others may result in
some loss of functionality
(such as lost display
messages).

Replace the device.

If this action does not solve
the problem, contact HP
support.

32 CHASSIS NVRAM
CONTENTS
CORRUPTED

Error

NVRAM is corrupt. The
system cannot continue
to operate.

Contact HP support.

40 BEGIN
REDUNDANCY
SUPPORT

Informational

The array controllers are
attempting to enter
redundant mode.

41 REDUNDANCY
ACTIVE ACTIVE
CONTROLLER

Informational

The array controllers are
now in redundant mode
and this array controller
is active with enabled
access to the configured
volumes on the MSA500
system.

42 REDUNDANCY
ACTIVE STANDBY
CONTROLLER

Informational

The array controllers are
now in redundant mode
and this array controller
is in standby, available
to be made active if the
current active array
controller fails, assuming
proper cabling and
installation.

continued