Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide
C-17
Table C-1: Display Messages
continued
Message Type
Description Action
67 CACHE
HARDWARE
TEMPORARILY
DISABLED
Informational
The cache memory
hardware is temporarily
disabled, typically
because either the
battery is not charged or
a capacity expansion
operation is occurring.
After the problem is
solved, the system
automatically enables
the cache.
If a capacity expansion
operation is occurring, wait
for the process to finish.
If the battery is not charged,
allow sufficient time for the
battery to charge or replace
the cache module.
If this action does not solve
the problem, contact HP
support.
68 OBSOLETE
CACHE DATA
DELETED
Informational
Old data that no longer
belongs to any current
configured volumes
exists in the cache
memory at power up.
The controller deleted
this data. This action
typically results when
cache modules are
migrated between array
controllers.
—
69 CACHE
BATTERIES LOW,
RECHARGING
Informational
The batteries on the
cache module are low;
the system is recharging
batteries.
—
70 CACHE
DISABLED NO
CONFIGURATION
Informational The
controller
has
disabled the cache
because the cache is
unconfigured.
Use ACU to configure the
cache.