Display Messages

C-30

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

123 TOO MANY
VOLUMES
DETECTED

Error The

controller

detected

more than 32 volumes
(maximum supported) at
power up.

This condition can occur
when the ACU migrates
a set of volumes from
one array controller to a
different array controller
that already contains
configured volumes.

The controller does not
add the migrated
volumes.

1.

Remove the migrated

drives.

2.

Run ACU.

3.

Delete any unneeded

volumes until the
number of existing
volumes plus the
number of volumes
awaiting migration is
equal to or less than 32
volumes.

4.

Add the migrated

volumes.

If this action does not solve
the problem, contact HP
support.

124 SPARES
CLEARED

Informational

A set of volumes have
been migrated from one
array controller to a
different array controller
that already contains
configured volumes. The
migrated volumes have
spares defined for them
that conflict with the
existing configuration.
The defined spares have
been deleted to allow the
migration to proceed.

Run ACU to reassign spare
drives as needed.

continued