beautypg.com

HP StorageWorks 500 Modular Smart Array User Manual

Page 129

background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-37



Table C-1: Display Messages

continued

Message Type

Description Action

402 STORAGE BOX
# FAN
DEGRADED

Error

The specified storage
enclosure indicates that
one of its fans is not
operating at full
efficiency. The fan may
eventually fail.

1.

Be sure that all

MSA500 system fans
are operating.

2.

Replace any failed

fans.

If this action does not solve
the problem, contact HP
support.

403 STORAGE BOX
# FAN HOT
INSERTED

Informational

The specified storage
enclosure indicates that
a fan was added.

404 STORAGE BOX
# FAN HOT
REMOVED

Informational

The specified storage
enclosure indicates that
a fan was removed.

405 STORAGE BOX
#
TEMPERATURE OK

Informational

The temperature sensor
in the storage enclosure
indicates that the
temperature is in the
normal operating range.

continued