Display Messages

C-26

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

108 VOLUME #
STATE MISSING
DRIVES

Error

The configured volume is
unusable because it is
missing too many of the
physical drives that
constitute the volume.

The controller will disable
this volume.

1.

Power down the

MSA500 system.

2.

Power down all

attached storage
enclosures.

3.

Remove and reinstall

all SCSI drives, and be
sure that they seat fully
in their bays.

4.

Check for proper

connections on the
cables between the
MSA500 system and
any attached storage
enclosures.

5.

Power up the attached

storage enclosures.

6.

Power up the MSA500

system.

If this action does not solve
the problem, contact HP
support.

continued