beautypg.com

HP StorageWorks 500 Modular Smart Array User Manual

Page 133

background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-41



Table C-1: Display Messages

continued

Message Type

Description Action

501 PCI
SUBSYSTEM
HARDWARE
FAILURE

Error

The array controller PCI
subsystem encountered
a critical error during the
power up sequence.

1.

Remove the failed array

controller.

2.

Wait 10 seconds.

3.

Reinstall the array

controller, and be sure
that it seats fully in the
chassis.

If this action does not solve
the problem, contact HP
support.

502 PCI BRIDGE
ASIC SELF TEST
FAILURE

Error

The array controller PCI
bridge ASIC has
encountered a critical
error during the power up
sequence.

1.

Remove the failed array

controller.

2.

Wait 10 seconds.

3.

Reinstall the array

controller, and be sure
that it seats fully in the
chassis.

If this action does not solve
the problem, contact HP
support.

513 UNCORRECTED
ECC MEMORY
ERROR SEEN

Error

The array controller has
detected an
uncorrectable error in the
ECC memory on the
memory cache board.

Remove the failed array
controller and replace the
cache module DIMM.

518
CONNECTION LOST

Error

The named connection
has been lost.

Check SCSI connections to
the server.

Also, the controller may
have a failed SCSI
controller chip.

519
CONNECTION
RESTORED

Informational

The named connection
has been restored.