HP StorageWorks 500 Modular Smart Array User Manual
Page 107

Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide
C-15
Table C-1: Display Messages
continued
Message Type
Description Action
61 DUAL CACHE
MODULE SIZE
MISMATCH
Error
The array controller has
two cache modules
attached, but they are of
different sizes. Both
cache modules must be
the same size.
1.
Remove the failed array
controller.
2.
Replace one of the
cache modules with a
different module with
the correct memory.
3.
Wait 10 seconds.
4.
Reinstall the array
controller, and be sure
that it seats fully in the
chassis.
62 CACHE MODULE
#
Informational
Displays the size of the
cache module inserted
into the respective cache
module slot.
—
63 VALID CACHE
DATA FOUND AT
POWER-UP
Informational
Valid host data exists in
the battery-backed cache
memory at power up.
The controller has
flushed this data to the
drives.
—
64 CACHE DATA
LOST BATTERY
DEAD
Error
The battery on the cache
memory is no longer
charged. If data existed
in the cache memory, it
is lost.
—
65 CACHE
HARDWARE
ENABLED
Informational
The cache hardware was
temporarily disabled, but
it is enabled again. This
message might result
from insufficient charge
on the batteries that are
now charged to capacity.
—
continued