beautypg.com

HP StorageWorks 500 Modular Smart Array User Manual

Page 107

background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-15



Table C-1: Display Messages

continued

Message Type

Description Action

61 DUAL CACHE
MODULE SIZE
MISMATCH

Error

The array controller has
two cache modules
attached, but they are of
different sizes. Both
cache modules must be
the same size.

1.

Remove the failed array

controller.

2.

Replace one of the

cache modules with a
different module with
the correct memory.

3.

Wait 10 seconds.

4.

Reinstall the array

controller, and be sure
that it seats fully in the
chassis.

62 CACHE MODULE
# MB

Informational

Displays the size of the
cache module inserted
into the respective cache
module slot.

63 VALID CACHE
DATA FOUND AT
POWER-UP

Informational

Valid host data exists in
the battery-backed cache
memory at power up.
The controller has
flushed this data to the
drives.

64 CACHE DATA
LOST BATTERY
DEAD

Error

The battery on the cache
memory is no longer
charged. If data existed
in the cache memory, it
is lost.

65 CACHE
HARDWARE
ENABLED

Informational

The cache hardware was
temporarily disabled, but
it is enabled again. This
message might result
from insufficient charge
on the batteries that are
now charged to capacity.

continued