beautypg.com

HP StorageWorks 500 Modular Smart Array User Manual

Page 125

background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-33



Table C-1: Display Messages

continued

Message Type

Description Action

204 ARRAY
CONTROLLER
DISABLED

Error

The array controller is
disabled because of a
redundancy failure.

1.

Remove the failed array

controller.

2.

Wait 10 seconds.

3.

Reinstall the array

controller, and be sure
that it seats fully.

If this action does not solve
the problem, contact HP
support.

205 ARRAY
CONTROLLER
RESTARTING

Informational

The array controller has
completed Controller
Firmware Auto Cloning
and is restarting
automatically.

300 RECOVERY
ROM AUTOFLASH
STARTED

Informational

Indicates that the array
controller detected that
the firmware’s backup
recovery ROM image is
invalid and is copying the
current active firmware
image into the backup
recovery ROM.

301 RECOVERY
ROM AUTOFLASH
DONE

Informational

Indicates that the array
controller successfully
completed the process of
copying the current
active firmware image
into the backup recovery
ROM.

continued