Display Messages

C-12

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

51 REDUNDANCY
FAILED I/O
REQUEST ERROR

Error While

either attempting

to enter redundant mode
or already operating in
redundant mode, one of
the array controllers
encountered an error
while sending I/O
between the two array
controllers over the
communication channel
between them.
Redundancy is disabled
at this time.

If the MSA500 system is
currently involved in host
I/O:

1.

Remove the standby

array controller.

2.

Wait 10 seconds.

3.

Reinstall the controller,

and be sure that it
seats fully in the
chassis.

If this action does not solve
the problem, wait until
downtime is available and
do the following:

1.

Power down the

MSA500 system.

2.

Remove both array

controllers.

3.

Reinstall both array

controllers, and be sure
that they seat fully in
the chassis.

If this action does not solve
the problem, contact HP
support.