Display Messages

C-38

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

406 STORAGE BOX
# OVERHEATING

Error

The temperature sensor
in the storage enclosure
indicates that the
enclosure is exceeding
the normal operating
range.

1.

Power down the

MSA500 system as
soon as possible to
avoid hardware failure.

2.

Be sure that all

MSA500 system fans
are operating.

3.

Replace any failed

fans.

4.

Be sure that all bays

are populated with
components or blanks.

If this action does not solve
the problem, contact HP
support.

407 STORAGE BOX
# OVERHEATED

Error

The temperature sensor
in the storage enclosure
indicates that the
enclosure exceeded the
safe operating range.

1.

Power down the

MSA500 system as
soon as possible to
avoid hardware failure.

2.

Be sure that all

MSA500 system fans
are operating.

3.

Replace any failed

fans.

4.

Be sure that all bays

are populated with
components or blanks.

If this action does not solve
the problem, contact HP
support.

continued