beautypg.com

HP StorageWorks 500 Modular Smart Array User Manual

Page 112

background image

Display Messages

C-20

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

73 CACHE
HARDWARE
BATTERIES
MISSING

Error

The cache memory
batteries are missing.

If the MSA500 system is
currently involved in host
I/O:

1.

Remove the standby

array controller.

2.

Wait 10 seconds.

3.

Reinstall the controller,

and be sure that it
seats fully in the
chassis.

If this action does not solve
the problem, wait until
downtime is available and
do the following:

1.

Power down the

MSA500 system.

2.

Remove both array

controllers.

3.

Reinstall both array

controllers, and be sure
that they seat fully in
the chassis.

If this action does not solve
the problem, contact HP
support.

80 REPLACEMENT
DRIVE FOUND BOX
# BAY

Informational

A SCSI drive that was
previously missing or
failed has been replaced
with a working SCSI
drive.

continued