HP StorageWorks 500 Modular Smart Array User Manual

Page 120

background image

Display Messages

C-28

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

112 VOLUME #
REBUILD FAILURE

Error

The rebuild operation on
the configured volume
failed.

If the volume is still
operating in regenerative
mode, remove the
replacement drive and
replace it with a different
new drive.

113 VOLUME #
EXPANSION
FAILURE

Error

The volume expansion
operation on the
configured volume failed.

Run ACU and determine the
state of the volume. If the
volume is still operational,
reattempt the operation.

114 VOLUME #
STATE DELETED

Informational

The configured volume is
deleted and no longer
available. Use ACU to
delete volumes.

120 CONFIGURED
VOLUMES

Informational The

controller

detected

the specified number of
configured volumes at
power up.

continued