Display Messages

C-14

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

54 REDUNDANCY
FAILED CACHE
DIMMS MISMATCH

Error

The cache memory
modules on two different
controllers are not the
same size. All cache
memory modules must
be the same size for
redundant mode.

1.

Remove the array

controller that has
halted.

2.

Replace the cache

memory with the
appropriately sized
DIMMs.

3.

Wait 10 seconds.

4.

Reinstall the array

controller, and be sure
that it seats fully in the
chassis.

60 NO CACHE
MODULE FOUND

Error

The array controller
requires at least one
cache module in order to
operate. The cache
module is not present or
it has failed.

1.

Remove the failed array

controller.

2.

Either add a cache

module or replace the
failed one.

3.

Wait 10 seconds.

4.

Reinstall the array

controller, and be sure
that it seats fully in the
chassis.

If this action does not solve
the problem, contact HP
support.

continued