Component Identification

HP StorageWorks Modular Smart Array 500 System User Guide

1-13



Table 1-9: Controller LEDs

continued

Item LED

Descriptions Status

11

Logical I/O activity

Green = Currently processing logical
requests from the host adapter.

Off = No processing of logical requests

12

SCSI bus 0 activity

13

SCSI bus 1 activity

Green = Outstanding requests on the
SCSI bus

Off = No outstanding requests

14

Cache activity

Green = Cache activity

Off = No cache activity

Flashing green = Cache transfer pending

15

Drive failure

Green = An array-configured drive has
failed.

Off = No drive failures

16

Active redundancy

Green = Controllers are operating with
redundancy.

Off = No redundancy

17

Fault

Amber = Error message received by
controller display.

Off = No error message received or no