HP StorageWorks 500 Modular Smart Array User Manual

Page 105

background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-13



Table C-1: Display Messages

continued

Message Type

Description Action

52 REDUNDANCY
FAILED PCI BUS
ERROR

Error While

either attempting

to enter redundant mode
or already operating in
redundant mode, one of
the array controllers
encountered a PCI bus
error on the
communication channel
used between the two
array controllers.
Redundancy is disabled
at this time.

If the MSA500 system is
currently involved in host
I/O:

1.

Remove the standby

array controller.

2.

Wait 10 seconds.

3.

Reinstall the controller,

and be sure that it
seats fully in the
chassis.

If this action does not solve
the problem, wait until
downtime is available and
do the following:

1.

Power down the

MSA500 system.

2.

Remove both array

controllers.

3.

Reinstall both array

controllers, and be sure
that they seat fully in
the chassis.

If this action does not solve
the problem, contact HP
support.

53 REDUNDANCY
FAILED NO SECOND
CONTROLLER

Error

While operating in
redundant mode, one of
the array controllers was
removed. Redundancy is
disabled at this time.

Reinstall the missing array
controller, and be sure that
it seats fully in the chassis.

continued