Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide
C-13
Table C-1: Display Messages
continued
Message Type
Description Action
52 REDUNDANCY
FAILED PCI BUS
ERROR
Error While
either attempting
to enter redundant mode
or already operating in
redundant mode, one of
the array controllers
encountered a PCI bus
error on the
communication channel
used between the two
array controllers.
Redundancy is disabled
at this time.
If the MSA500 system is
currently involved in host
I/O:
1.
Remove the standby
array controller.
2.
Wait 10 seconds.
3.
Reinstall the controller,
and be sure that it
seats fully in the
chassis.
If this action does not solve
the problem, wait until
downtime is available and
do the following:
1.
Power down the
MSA500 system.
2.
Remove both array
controllers.
3.
Reinstall both array
controllers, and be sure
that they seat fully in
the chassis.
If this action does not solve
the problem, contact HP
support.
53 REDUNDANCY
FAILED NO SECOND
CONTROLLER
Error
While operating in
redundant mode, one of
the array controllers was
removed. Redundancy is
disabled at this time.
Reinstall the missing array
controller, and be sure that
it seats fully in the chassis.
continued