beautypg.com

HP StorageWorks 500 Modular Smart Array User Manual

Page 127

background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-35



Table C-1: Display Messages

continued

Message Type

Description Action

305 ROM CLONING
FAILED

Error

Indicates that the two
array controllers in a
MSA500 system failed
the firmware cloning
process.

1.

Remove the failing

array controller.

2.

Wait 10 seconds.

3.

Reinstall the array

controller, and be sure
that it seats fully in the
chassis.

The controller reattempts
the controller firmware auto
cloning process again.

If this action does not solve
the problem, contact HP
support.

306 FIRMWARE
FLASH STARTED

Informational

Indicates that the array
controller in the MSA500
system is flashing the
firmware.

Do not power down the
system until the process is
complete.

The process could take up
to 5 minutes.

307 FIRMWARE
FLASH DONE

Informational

Indicates that the array
controller in the MSA500
system completed the
firmware flash process.

Power down the system.

308 FIRMWARE
FLASH FAILED

Error

Indicates that the array
controller in the MSA500
system failed the
firmware flash process.

Attempt the flash process
again.

If this action does not solve
the problem, contact HP
support.

continued