HP StorageWorks 500 Modular Smart Array User Manual
Page 128

Display Messages
C-36
HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages
continued
Message Type
Description Action
309 EMU FLASH
STARTED
Informational
Indicates that the I/O
EMU in the MSA500
system is flashing the
firmware.
Do not power down the
system until the process is
complete.
The process could take up
to 5 minutes.
If this action does not solve
the problem, contact HP
support.
310 EMU FLASH
DONE
Informational
Indicates that the I/O
EMU in a MSA500
system completed the
firmware flash process.
Power down the system.
311 EMU FLASH
FAILED
Error
Indicates that the I/O
EMU in a MSA500
system has failed the
firmware flash process.
Attempt the flash process
again.
If this action does not solve
the problem, contact HP
support.
400 STORAGE BOX
#
Informational
The specified storage
enclosure indicates that
one of its previously
failed or degraded fans is
now operating normally.
—
401 STORAGE BOX
#
Error
The specified storage
enclosure indicates that
one of its fans has failed.
The storage enclosure
and any devices in it may
now be susceptible to
overheating if corrective
action is not taken.
1.
Be sure that all
MSA500 system fans
are operating.
2.
Replace any failed
fans.
If this action does not solve
the problem, contact HP
support.
continued