HP StorageWorks 500 Modular Smart Array User Manual
Page 114
Display Messages
C-22
HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages
continued
Message Type
Description Action
85 BAD DRIVE
FRMWARE BOX
#
Error
A SCSI drive has corrupt
firmware. Continued use
of this drive could result
in drive failure,
decreased performance,
or data loss.
Do one of the following:
•
Update the drive
firmware. Refer to
Chapter 3, “Hardware
Options Installation.”
•
Replace the drive as
soon as possible. Refer
to “Recovering from
Hard Drive Failure” in
Appendix D.
If this action does not solve
the problem, contact HP
support.
86 DRIVE POSITION
CHANGE
DETECTED
Informational
The physical drive
locations have changed
for SCSI drives that
constitute a configured
volume within the
MSA500 system or an
attached storage
enclosure.
The array controller has
updated its configuration
information accordingly.
—
87 DRIVE POSITION
CHANGE INVALID
Informational
The physical drive
locations have changed
for SCSI drives that
constitute a configured
volume within the
MSA500 system or an
attached storage
enclosure.
The array controller can
no longer access the
configured volume.
1.
Power down the
MSA500 system.
2.
Restore the drives to
their original positions.
If this action does not solve
the problem, contact HP
support.