Display Messages

C-32

HP StorageWorks Modular Smart Array 500 System User Guide



Table C-1: Display Messages

continued

Message Type

Description Action

202 ARRAY
CONTROLLER
OVERHEATING

Error

The temperature sensor
on the array controller
indicates that the array
controller is exceeding
the normal operating
range.

1.

Be sure that all

MSA500 system fans
are operating.

2.

Replace any failed

fans.

3.

Be sure that all bays

are populated with
components or blanks.

If this action does not solve
the problem, contact HP
support.

203 ARRAY
CONTROLLER
OVERHEATED

Error

The temperature sensor
on the array controller
indicates that the array
controller exceeded the
safe operating range.

1.

Power down the

MSA500 system as
soon as possible to
avoid hardware failure.

2.

Be sure that all

MSA500 system fans
are operating.

3.

Replace any failed

fans.

4.

Be sure that all bays

are populated with
components or blanks.

If this action does not solve
the problem, contact HP
support.

continued