HP StorageWorks 500 Modular Smart Array User Manual

Page 119

background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-27



Table C-1: Display Messages

continued

Message Type

Description Action

109 VOLUME #
STATE WRONG
DRIVE REPLACED

Error

The controller recognizes
drive replacement on
working physical drives
rather than failed drives.

1.

Power down the

MSA500 system.

2.

Reinstall the working

drives.

3.

Replace the failed

drives.

4.

Power up the MSA500

system.

110 VOLUME #
EXPANSION
DISABLED

Informational The

controller

disabled

volume expansion
operation on the
configured volume. This
condition can result from
the following:

An ongoing rebuild
operation

Another expansion
operation

Disabled cache
memory caused by
a low battery

The expansion resumes
after the condition has
been cleared.

Wait for the current
operation to finish.

If the condition does not
change, replace the cache
module.

111 VOLUME #
INITIALIZING
PARITY

Informational

The array controller is
calculating and storing
parity information for the
configured volume and
performance may be
lower until this operation
is complete.

continued