HP StorageWorks 500 Modular Smart Array User Manual
Page 95
Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide
C-3
Table C-1: Display Messages
continued
Message Type
Description Action
08 FIRMWARE
FLASH FAILED
Error
The active controller was
unable to clone the
firmware onto a
redundant controller after
two consecutive
attempts.
Remove the failed
controller.
20 INITIALIZING
SCSI SUBSYSTEM
Informational
The SCSI subsystem is
being initialized as part
of the power on
sequence.
—
21 SCANNING FOR
SCSI DEVICES
Informational
The controller is
scanning for hard drives.
—
22 INITIALIZING
SCSI DEVICES
Informational
The controller is
initializing the hard
drives.
—
24 BAD SCSI BUS
MODE NON-LVD
DEVICE FOUND
Error
The MSA500 system
does not support SCSI
Single Ended (SE)
devices; it only supports
SCSI Low Voltage
Differential (LVD)
devices.
1.
Power down the
MSA500 system.
2.
Examine all attached
SCSI devices.
3.
Remove any SE
devices found and
replace them with LVD
devices.
30 I2C READ
FAILURE
Error
Read access has failed
to an internal device on
an I2C hardware bus.
Certain I2C devices are
considered critical and
will result in a failure of
the array controller while
others may result in
some loss of functionality
(such as lost display
messages).
Replace the device.
If this action does not solve
the problem, contact HP
support.
continued