Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-3



Table C-1: Display Messages

continued

Message Type

Description Action

08 FIRMWARE
FLASH FAILED

Error

The active controller was
unable to clone the
firmware onto a
redundant controller after
two consecutive
attempts.

Remove the failed
controller.

20 INITIALIZING
SCSI SUBSYSTEM

Informational

The SCSI subsystem is
being initialized as part
of the power on
sequence.

21 SCANNING FOR
SCSI DEVICES

Informational

The controller is
scanning for hard drives.

22 INITIALIZING
SCSI DEVICES

Informational

The controller is
initializing the hard
drives.

24 BAD SCSI BUS
MODE NON-LVD
DEVICE FOUND

Error

The MSA500 system
does not support SCSI
Single Ended (SE)
devices; it only supports
SCSI Low Voltage
Differential (LVD)
devices.

1.

Power down the

MSA500 system.

2.

Examine all attached

SCSI devices.

3.

Remove any SE

devices found and
replace them with LVD
devices.

30 I2C READ
FAILURE name>

Error

Read access has failed
to an internal device on
an I2C hardware bus.

Certain I2C devices are
considered critical and
will result in a failure of
the array controller while
others may result in
some loss of functionality
(such as lost display
messages).

Replace the device.

If this action does not solve
the problem, contact HP
support.

continued