Display Messages
C-2
HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages
continued
Message Type
Description Action
03 CRITICAL LOCK-
UP DETECTED.
CODE=
Error
Array controller firmware
detected a critical error.
To prevent any possible
data loss, the firmware
has entered a lock-up
state. The code contains
engineering-specific
information about the
lock-up condition.
Contact HP support.
1.
Remove the failing
array controller.
2.
Wait 10 seconds.
3.
Reinstall the array
controller, and be sure
that it seats fully in the
chassis.
If this action does not solve
the problem, contact HP
support.
04 ENABLE
VOLUMES ? ‘<’=NO,
‘>’=YES
User Input
An issue exists with all
configured volumes that
may result in data loss.
Refer to display messages
for more information.
05 SYSTEM NAME:
Informational
Displays the user
assigned name for the
MSA500 system. This
name can be assigned
using ACU.
—
06 RESTARTING
SYSTEM
Informational
Indicates that the system
has been reset and is
being restarted.
—
07 CLONE
FIRMWARE?
‘<=NO,’ ‘>=YES
User Input
The controller is
attempting to enter
redundant mode but
needs to clone the
firmware. The controller
is requesting
confirmation from the
user to overwrite the
current firmware with the
version from the
redundant controller.
If the user selects YES, the
firmware is cloned.
If the user selects NO, the
firmware disables the
controller.
If the user does not respond
within 60 seconds, the
controller clones the
firmware.
continued