beautypg.com

HP StorageWorks 500 Modular Smart Array User Manual

Page 113

background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-21



Table C-1: Display Messages

continued

Message Type

Description Action

81 SMART DRIVE
ALERT BOX #,
BAY

Informational

A SCSI drive may be
close to failing. The
prefailure condition was
determined either by the
drive firmware using
SMART technology or by
the array controller using
monitor and performance
testing.

Replace the drive as soon
as possible. Refer to
“Recovering from Hard
Drive Failure” in
Appendix D.

82 DRIVE HOT
ADDED BOX #,
BAY

Informational

A SCSI drive has been
added to the MSA500
system or to one of the
storage enclosures
attached to it.

83 DRIVE HOT
REMOVED BOX
#, BAY

Informational

A SCSI drive has been
removed from the
MSA500 system or from
one of the storage
enclosures attached to it.

84 DRIVE FAILURE
BOX #, BAY

Error

A SCSI drive in the
MSA500 system or in
one of the storage
enclosures attached to it
has failed. If the drive
was part of a configured
volume, the state of the
volume depends on the
fault tolerance used.

Replace the drive as soon
as possible. Refer to
“Recovering from Hard
Drive Failure” in
Appendix D.

continued