Press
%
from the power-up screen to enter the General Setup menu (Figure 3-6), then high-
light Max/Min Settings. Press
!
to enter the Max/Min Settings submenu (Figure 3-7). (If a
Password is required, see PAR. 3.2.4.4 for instructions.) Highlight Protect Entry and press
!
to
change it. Highlight Bipolar or Independent, then
$
to save, or
%
to abort. When complete,
press
$
to save for power-up, or
#
to abort, or
%
to apply the changes (without saving for
power-up) and exit.
FIGURE 3-6. GENERAL SETUP MENU
FIGURE 3-7. MAX/MIN SETTINGS MENU
Selection of Bipolar does not immediately change the protect limit values; it changes how the
protect settings are displayed and set from the power-up screen. So if
maximum/minimum
pro-
tection limits were set to different values, (e.g, for BOP 36-28MG, current mode, no load, +V
Protect Max = 25V and –V Protect Min = 7V) when BIPOLAR is selected, the previous protec-