beautypg.com

KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.2.01 to 2.37 User Manual

Page 27

background image

BOP HIPWR 022108

1-9

GENERAL (ENVIRONMENTAL) CHARACTERISTICS

Temperature

operating

0 to +50 deg C

Full rated load

storage

-20 to +85 deg C

Cooling

Two internal fans

exhaust to the rear

Humidity

0 to 95% RH

non-condensing

Shock

20g. 11msec ±50% half sine

non-operating

Vibration

5-10HZ:

10mm double amplitude

3 axes, non-operating

10-55HZ:

2g

3 axes, non-operating

Altitude

sea level to 10,000 feet

Safety Certification

a-c power

UL 3101-1 and EN 6101-1

Pending

PHYSICAL CHARACTERISTICS

Dimensions

English

5.25' X 19" X 21.5"

H X W X D

metric

133.3mm X 482.6mm X 546.1mm

H X W X D

Weight, 1000W models

English

53 lbs

metric

24.1Kg

Connections

Source power

3-pin IEC connector

Load connections

Nickel-plated copper bus bars

Sensing Output

Terminal Block

7-pin terminal block

Default: 3 links installed for local sensing and
ground network connected.

Analog I/O control port

15-pin D female

See Figure 2-1, Table 2-10

PAR/SER CTRL IN

port

8-pin mini DIN connector

See Figure 2-1, Table 2-7

PAR/SER CTRL OUT

port

4-pin mini DIN connector

See Figure 2-1, Table 2-6

PAR/SER PROT IN

port

8-pin phone jack

See Figure 2-1, Table 2-8

PAR/SER PROT OUT

port

8-pin phone jack

See Figure 2-1, Table 2-9

EXT PROT port

6-pin phone jack

See Table 2-4

Primary digital port

24-pin GPIB connector

IEEE 488 port - See Table 2-11

Secondary digital

ports

6-pin phone jack

RS 232 port - See Table 2-5

5-pin mini DIN female connector

IEEE 1118 port - See Table 2-2

External Trigger

4-pin stereo audio phone jack

See Table 2-3

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION