1-8

BOP HIPWR 022108

MISCELLANEOUS FEATURES

Maximum/Minimum Settings

Protection Limit Type

Bipolar (default) or Independent

Main Channel

0 to EO

NOM

or IO

NOM

(default)

Software limit to setting of main channel
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode

Protection Limit Channel

(maximum value, Internal)

EO

MIN

or IO

MIN

to

1.01 EO

NOM

or IO

NOM

(internal)

Software limit to setting of protection limit
channel.
Voltage (Volts) for Current mode
Current (Amperes) for Voltage mode

Load Type Settings

Active (default), Resistive,

Battery, Custom

Consult factory for custom setting.

MISCELLANEOUS FEATURES (Continued)

Self-test capabilities

Display, Keypad, Interface, Serial

Interface, Analog, Output

Serial Interface test requires Loop Back Test
connector (p/o KIT 219-0436, see Table 1-5).

Interface Settings

Data Format

SCPI (default), CIIL

GPIB Address

0 to 30 (6 = default)

Output Status @ Reset

ON or OFF (OFF = default)

Serial Baud Rate

Off, 9600, 19200 (Off = default)

Device Clear

SCPI (default) or MATE

XON/XOFF

Enable (default) or Disable

Prompt

Disable (default), Enable,

Enable with Echo

Calibration

Assisted by front-panel prompts

Power-up Settings

Mode

Voltage (default) or Current

Main Channel

Reference Type

Internal (default), External or External

Reference Level (Gain Mode)

Protection Limit Channel

Reference type

Internal (default), External

or Lesser Limit

Applies to Limit channel

Protection Limit Levels

(Internal)

EO

MIN

or IO

MIN

to

1.01 EO

NOM

or IO

NOM

Voltage (Volts) for Current mode,
Current (Amperes) for Voltage mode

Output status

On (default) or Off

Password

Types

Main, Admin1, Admin2

Factory defaults: Main: DEFAULT,
Admin1: A, Admin2: KEPCO

Protection Choices Unprotected, Main, Admin1, Admin2 Password menu always protected by Admin2

Items Protected Interface, max/min , Load type, Test,

Calibration, Power-up, Keypad @

local, Keypad lockout at power-up,

Save Display Chg

(See Figure 3-5 for defaults)

Multiple unit configurations are protected by
Admin2 password.

Save Display Chg choice is Enable or Dis-
able; when set to Disable, prevents changes
made to the display settings from being saved
for power up.

Series, Parallel, Series x Parallel configurations of
identical units

Single, Parallel, Series, 2 X 2, 3 X 2 2 X 2 is two parallel branches of two series-

connected identical units.
3 X 2 is two parallel branches of three series-
connected identical units.

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION