KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.2.01 to 2.37 User Manual
Page 26

1-8
BOP HIPWR 022108
MISCELLANEOUS FEATURES
Maximum/Minimum Settings
Protection Limit Type
Bipolar (default) or Independent
Main Channel
0 to EO
NOM
or IO
NOM
(default)
Software limit to setting of main channel
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode
Protection Limit Channel
(maximum value, Internal)
EO
MIN
or IO
MIN
to
1.01 EO
NOM
or IO
NOM
(internal)
Software limit to setting of protection limit
channel.
Voltage (Volts) for Current mode
Current (Amperes) for Voltage mode
Load Type Settings
Active (default), Resistive,
Battery, Custom
Consult factory for custom setting.
MISCELLANEOUS FEATURES (Continued)
Self-test capabilities
Display, Keypad, Interface, Serial
Interface, Analog, Output
Serial Interface test requires Loop Back Test
connector (p/o KIT 219-0436, see Table 1-5).
Interface Settings
Data Format
SCPI (default), CIIL
GPIB Address
0 to 30 (6 = default)
Output Status @ Reset
ON or OFF (OFF = default)
Serial Baud Rate
Off, 9600, 19200 (Off = default)
Device Clear
SCPI (default) or MATE
XON/XOFF
Enable (default) or Disable
Prompt
Disable (default), Enable,
Enable with Echo
Calibration
Assisted by front-panel prompts
Power-up Settings
Mode
Voltage (default) or Current
Main Channel
Reference Type
Internal (default), External or External
Reference Level (Gain Mode)
Protection Limit Channel
Reference type
Internal (default), External
or Lesser Limit
Applies to Limit channel
Protection Limit Levels
(Internal)
EO
MIN
or IO
MIN
to
1.01 EO
NOM
or IO
NOM
Voltage (Volts) for Current mode,
Current (Amperes) for Voltage mode
Output status
On (default) or Off
Password
Types
Main, Admin1, Admin2
Factory defaults: Main: DEFAULT,
Admin1: A, Admin2: KEPCO
Protection Choices Unprotected, Main, Admin1, Admin2 Password menu always protected by Admin2
Items Protected Interface, max/min , Load type, Test,
Calibration, Power-up, Keypad @
local, Keypad lockout at power-up,
Save Display Chg
(See Figure 3-5 for defaults)
Multiple unit configurations are protected by
Admin2 password.
Save Display Chg choice is Enable or Dis-
able; when set to Disable, prevents changes
made to the display settings from being saved
for power up.
Series, Parallel, Series x Parallel configurations of
identical units
Single, Parallel, Series, 2 X 2, 3 X 2 2 X 2 is two parallel branches of two series-
connected identical units.
3 X 2 is two parallel branches of three series-
connected identical units.
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION