TABLE 3-4. VOLTAGE AND CURRENT PARAMETER DEFINITIONS

Term

Definition

To modify

refer to PAR.

Local

Remote

+E

Onom

–E

Onom

The nominal (rated) output voltage of the unit determined by model; e.g. for
a BOP 36-28MG, ±E

Onom

is 36V.

N/A

N/A

+I

Onom

–I

Onom

The nominal (rated) output current of the unit determined by model; e.g. for
a BOP 36-28MG, ±I

Onom

is 28A.

N/A

N/A

+Voltage
–Voltage

Voltage mode only. Positive (+) and negative (–) output voltage values
established by keypad or remote command.
Range (+): 0 to +Voltage max
Range (–): 0 to –Voltage min

3.3.3

B.67

+Voltage max
–Voltage min

Voltage mode only. Maximum (positive) and minimum (maximum
negative) voltage that can be set.
Value (+): 0 to +E

Onom

Value (–): 0 to –E

Onom

3.3.4.1

B.69, B.70,

B.71, B.73

+Current Protect
–Current Protect

Voltage mode only. Defines maximum (+) current and Minimum (maximum
negative) (–) that unit can source or sink.
Range (+): +Current Protect min to +Current Protect max
Range (–): –Current Protect max to –Current Protect min

3.3.3

B.51, B.52,

B.57, B.55

+Current Protect Max
–Current Protect Min

Voltage mode only. Maximum setting for +Current Protect and Minimum
(maximum negative) setting for –Current Protect.
Value (+): +Current Protect min to (1.01 x +Current max)
Value (–): –Current Protect max to (1.01 x –Current min)

3.3.4.2

B.59, B.60,

B.63, B.61

Minimum (box)
+Current Protect Min
–Current Protect Max

Voltage mode only. Minimum (positive) setting for +Current Protect and
maximum (maximum negative) setting for –Current Protect. Values of ±Cur-
rent Protect between +Current Protect Min and –Current Protect Max (near
zero) are not allowed.This zone (also referred to as the minimum (box) is
automatically calculated by the BOP (see Figure 1-2).

N/A

N/A

+Voltage Protect
–Voltage Protect

Current mode only. Maximum positive (+) and minimum (maximum
negative) (–) voltage that can appear at the output.
Range (+): +Voltage Protect min to +Voltage Protect max
Range (–): –Voltage Protect max to –Voltage Protect min

3.3.3

B.77, B.78,

B.83, B.81

+Voltage Protect Max
–Voltage Protect Min

Current mode only. Maximum (positive) setting for +Voltage Protect and
Minimum (maximum negative) setting for –Voltage Protect.
Value (+): +Voltage Protect min to (1.01 x +Voltage max)
Value (–): –Voltage Protect max to (1.01 x –Voltage min)

3.3.4.2

B.85, B.86,

B.89, B.87

Minimum (box)
+Voltage Protect Min
–Voltage Protect Max

Current mode only. Minimum (positive) setting for +Voltage Protect and
maximum (maximum negative) setting for –Voltage Protect. Values of ±Volt-
age Protect between +Voltage Protect Min and –Voltage Protect Max (near
zero) are not allowed. This zone (also referred to as the minimum (box) is
automatically calculated by the BOP (see Figure 1-2).

N/A

N/A

+Current
–Current

Current mode only. Positive and negative output current established by
keypad or remote command.
Range (+): 0 to +Current max
Range (–): 0 to –Current min

3.3.3

B.41

+Current max
–Current min

Current mode only. Maximum (positive) and minimum (maximum
negative) current that can be set.
Value (+): 0 to +I

Onom

Value (–): 0 to –I

Onom

3.3.4.1

B.43, B.44,

B.47, B.45