B.32 [source:]list:query command, B.33 [source:]list:query? query, B.32 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.2.01 to 2.37 User Manual
Page 155: Sour, B.33, B.32, b.33, List:quer

BOP-1K 022108
B-9
B.32 [SOURce:]LIST:QUERy COMMAND
LIST:QUER
Syntax:
Short Form: LIST:QUER
Long Form: LIST:QUERy
int_value =
Description: Determines first location to be queried by LIST:VOLT?, LIST:CURR? or LIST:DWEL? queries.
Related Commands: LIST:VOLT?, LIST:CURR?, LIST:DWEL?. LIST:QUER?. (See example, Figure B-2.)
B.33 [SOURce:]LIST:QUERy? QUERY
LIST:QUER?
Syntax:
Short Form: LIST:QUER?
Long Form: LIST:QUERy?
Return Value:
Description: Identifies first location to be queried by LIST:VOLT?, LIST:CURR?, LIST:DWEL? queries.
Related Commands: LIST:QUER, LIST:CURR?, LIST:DWEL?. LIST:QUER?. (See example, Figure B-2.)
FIGURE B-2. USING LIST COMMANDS AND QUERIES (SHEET 2 OF 2)
.
VOLT:MODE LIST
Executes the list. For 240 milliseconds the BOP outputs -20V, then output a
staircase triangle wave from -20V to +20V and back down to -20V. This
staircase will have a uniform spacing between voltage changes of 10 milli-
seconds and will repeat 100 times.
VOLT?
Returns +20 (the last step in the list set the unit to +20V.
LIST:COUNT?
Returns 100.
LIST:COUNT 10
Determines that the list will be repeated 10 times when executed.
LIST:COUNT?
Returns 10.
VOLT:MODE LIST
Initiates execution of the list. The unit outputs a sawtooth waveform that
increases from -20V to +20V and repeats 10 times. There is an abrupt
change from +20V to -20V each time the list transitions from location 20 to
location 0.
VOLT?
Returns 20, (the last step in the list set the unit to 20V.
LIST:DWELL .01,.01,.01,.01,.01,.01,.01,.01,.01
Enters dwell time of 0.01 seconds in locations 1 through 9.
LIST:DWELL .03
Enters dwell time of 0.03 second in location 10.
VOLT:MODE LIST
the list is not executed, the unit returns error -221,Settings Error indicating
the lists are not balanced.
LIST:DWELL:POINTS?
Returns 11 to indicate the dwell list has 11 entries
LIST:VOLT:POINTS?
Returns 21 to indicate the voltage list has 21 entries.
LIST:DWELL .01,.01,.01,.01,.01,.01,.01,.01,.01,.01
Dwell times are entered in locations 11 through 20.
DWELL:POINTS?
Returns 21 indicating there are now 21 step dwell times on the list.
LIST:QUER?
Returns 0 indicating list queries will start from location 0
LIST:QUER 9
Causes list queries to start at location 18
LIST:DWEL?
Returns 01,.03,.01,.01,.01,.01,.01,.01,.01,.01,.01,.01(the dwell times for
locations 9 through 20.
LIST COUNT 0
List will repeat indefinitely.
VOLT:MODE LIST
The list is executed. Stair case wave now consists of 21 steps of .01 sec-
onds except for the 0V step (location 10) which outputs 0V for 0.03 second.
LIST:DWEL?
Returns error -221,Settings Error because a LIST command cannot be exe-
cuted while the LIST is still being executed.
VOLT:MODE FIX
Stops execution of the list
LIST:VOLT:APPLY SINE,60,20 Adds a 60Hz, 20V p-p sine wave to the current waveform
VOLT:MODE:LIST
Unit outputs the staircase and then the sine wave.
*RST
Unit stops generating the waveform.