beautypg.com

B.32 [source:]list:query command, B.33 [source:]list:query? query, B.32 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.2.01 to 2.37 User Manual

Page 155: Sour, B.33, B.32, b.33, List:quer

background image

BOP-1K 022108

B-9

B.32 [SOURce:]LIST:QUERy COMMAND

LIST:QUER

Syntax:

Short Form: LIST:QUER
Long Form: LIST:QUERy
int_value = where n = first location to be queried.

Description: Determines first location to be queried by LIST:VOLT?, LIST:CURR? or LIST:DWEL? queries.

Related Commands: LIST:VOLT?, LIST:CURR?, LIST:DWEL?. LIST:QUER?. (See example, Figure B-2.)

B.33 [SOURce:]LIST:QUERy? QUERY

LIST:QUER?

Syntax:

Short Form: LIST:QUER?

Long Form: LIST:QUERy?

Return Value:

Description: Identifies first location to be queried by LIST:VOLT?, LIST:CURR?, LIST:DWEL? queries.

Related Commands: LIST:QUER, LIST:CURR?, LIST:DWEL?. LIST:QUER?. (See example, Figure B-2.)

FIGURE B-2. USING LIST COMMANDS AND QUERIES (SHEET 2 OF 2)

.
VOLT:MODE LIST

Executes the list. For 240 milliseconds the BOP outputs -20V, then output a
staircase triangle wave from -20V to +20V and back down to -20V. This
staircase will have a uniform spacing between voltage changes of 10 milli-
seconds and will repeat 100 times.

VOLT?

Returns +20 (the last step in the list set the unit to +20V.

LIST:COUNT?

Returns 100.

LIST:COUNT 10

Determines that the list will be repeated 10 times when executed.

LIST:COUNT?

Returns 10.

VOLT:MODE LIST

Initiates execution of the list. The unit outputs a sawtooth waveform that
increases from -20V to +20V and repeats 10 times. There is an abrupt
change from +20V to -20V each time the list transitions from location 20 to
location 0.

VOLT?

Returns 20, (the last step in the list set the unit to 20V.

LIST:DWELL .01,.01,.01,.01,.01,.01,.01,.01,.01

Enters dwell time of 0.01 seconds in locations 1 through 9.

LIST:DWELL .03

Enters dwell time of 0.03 second in location 10.

VOLT:MODE LIST

the list is not executed, the unit returns error -221,Settings Error indicating
the lists are not balanced.

LIST:DWELL:POINTS?

Returns 11 to indicate the dwell list has 11 entries

LIST:VOLT:POINTS?

Returns 21 to indicate the voltage list has 21 entries.

LIST:DWELL .01,.01,.01,.01,.01,.01,.01,.01,.01,.01

Dwell times are entered in locations 11 through 20.

DWELL:POINTS?

Returns 21 indicating there are now 21 step dwell times on the list.

LIST:QUER?

Returns 0 indicating list queries will start from location 0

LIST:QUER 9

Causes list queries to start at location 18

LIST:DWEL?

Returns 01,.03,.01,.01,.01,.01,.01,.01,.01,.01,.01,.01(the dwell times for
locations 9 through 20.

LIST COUNT 0

List will repeat indefinitely.

VOLT:MODE LIST

The list is executed. Stair case wave now consists of 21 steps of .01 sec-
onds except for the 0V step (location 10) which outputs 0V for 0.03 second.

LIST:DWEL?

Returns error -221,Settings Error because a LIST command cannot be exe-
cuted while the LIST is still being executed.

VOLT:MODE FIX

Stops execution of the list

LIST:VOLT:APPLY SINE,60,20 Adds a 60Hz, 20V p-p sine wave to the current waveform
VOLT:MODE:LIST

Unit outputs the staircase and then the sine wave.

*RST