FUNCTION GENERATOR CHARACTERISTICS (Continued)

Maximum number of points per basic waveform

Local: 3933
Remote: Can be set to either 3933 (normal resolution- default value) or 5760 (high
resolution), using the LIST:RES command.
• Each basic waveform (sine, triangle, ±ramp, square and level) is constructed using

a different number of points, depending on the basic waveform, type and fre-
quency. The number of points is inversely proportional to the frequency. For exam-
ple, a "local" sine segment of 0.01Hz uses almost the maximum number of points,
3840. Similar, a single segment of a "remote" high resolution sine segment at a
frequency bellow 1Hz uses the maximum number of points, 5760.

• Due to the different number of points of the basic waveforms (except square and

level) THD-F (Total Harmonic Distortion relative to the fundamental frequency)
and linearity for ramp and triangle waveforms are frequency dependent. For exam-
ple for a sine segment, the THD-F is 5% at 400Hz and 1.6% at 40Hz.

Count (Number of repetitions)

Range: 1 to 255

For Count = 0 the waveform is exe-

cuted indefinitely until stop com-

mand is sent

• Local: When the count is complete or if

execution is stopped using

%

, the output

of the unit is set to OFF (Standby indicator
lit). Output must be enabled (press
STANDBY) to execute the waveform
again.

• Remote: When the count is complete or

the waveform is stopped using the
VOLT:MODE FIX command, the output
gpes to zero (main channel reference pro-
grammed to zero).

Waveform Name

10 characters maximum

Waveform Parameters

Type: Voltage or Current

Positive Protection Limit:

(Vd-c or Ad-c)

Negative Protection Limit:

(Vd-c or Ad-c)

Count: number

Initial/Repeating

• Type of waveform, voltage or current, can

be selected only for a new waveform and
consequently applies to all waveform seg-
ments. Changing the type for an existing
waveform is not possible, unless the wave-
form is erased first.

• The Limit values (positive/negative) and

the count number apply to all waveform
segments and can be edited at the begin-
ning of a new waveform or later when mod-
ifying a waveform (see PAR. 3.3.9.7).

• All segments except the last may be set to

run once (Initial) or per the Count setting
(Repeating).

Basic waveform parameters

Sine: Frequency (Hz), Amplitude (Vp-p or Ap-p), Offset (Vd-c or Ad-c),

Start Phase (°), Stop Phase (°).

Triangular: Frequency (Hz), Amplitude (Vp-p or Ap-p), Offset (Vd-c or Ad-c), Start

Phase (°), Stop Phase (°).

Ramp (Pos. or Neg.): Frequency (Hz), Amplitude (Vp-p or Ap-p),

Offset (Vd-c or Ad-c).

Square: Frequency (Hz), Amplitude (Vp-p or Ap-p), Offset (Vd-c or Ad-c).
Level: Timing (sec), Amplitude (Vd-c or Ad-c).
• Local: the Start/Stop phases, available for sine and triangle only, can be set or

edited by modifying the existing segment (see PAR. 3.3.9.7).

• Remote: the start/stop phases are global parameters, applicable to all sine/ trian-

gular waveform segments.

• The Start/Stop points are independent and can have any value between 0° and

360°.

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION