4.3.1

CALIBRATION PROCEDURE USING SCPI COMMANDS

The following procedure provides a complete calibration of the unit. Steps 14 and 15 calibrate
the control signal used when the unit is a slave in series configurations. Steps 29 and 30 cali-
brate the control signal used when the unit is a master in parallel configurations. Steps 31 and
32 calib
rate the control signal used when the unit is a slave in parallel configurations. There is
no need for a special calibration step when the unit is used as a master in series configurations
since the BOP output voltage (which is calibrated by this procedure) is used to control the next
unit in series.

NOTES:

1. For ZERO calibration, adjust output to obtain value closest to zero.

TABLE 4-4. CURRENT CALIBRATION MEASUREMENTS AND TOLERANCES

MODEL

SENSE

RESISTOR

VALUE

(SEE NOTE AND

TABLE 4-2)

CURRENT

ZERO

±FULL SCALE

CURRENT

±FULL SCALE

CPR LIMIT

BOP 10-75MG

0.001 Ohm

0V

±0.008mV

0.075V (MAX)

–0.075V (MIN)

±0.008mV

0.075V (MAX)

–0.075V (MIN)

±0.038mV

BOP 20-50MG

0.001 Ohm

0V

±0.005mV

0.05V (MAX)

–0.05V (MIN)

±0.005mV

0.05V (MAX)

–0.05V (MIN)

±0.025mV

BOP 36-28MG

0.001 Ohm

0V

±0.003mV

0.028V (MAX)

–0.028V (MIN)

±0.003mV

0.028V (MAX)

–0.028V (MIN)

±0.014mV

BOP 50-20MG

0.01 Ohm

0V

±0.02mV

0.2V (MAX)

–0.2V (MIN)

±0.02mV

0.2V (MAX)

–0.2V (MIN)

±0.10mV

BOP 72-14MG

0.01 Ohm

0V

±0.014mV

0.14V (MAX)

–0.14V (MIN)

±0.014mV

0.14V (MAX)

–0.14V (MIN)

±0.07mV

BOP 100-10MG

0.01 Ohm

0V

±0.01mV

0.1V (MAX)

–0.1V (MIN)

±0.01mV

0.1V (MAX)

–0.1V (MIN)

±0.05mV

REFER TO NOTES FOR SENSE

RESISTOR VALUE OTHER

THAN LISTED HERE

R

SENSE
SEE

NOTE.

SEE

NOTE A.

SEE NOTE B.

SEE NOTE C.

USE SPACE PROVIDED AT

RIGHT FOR CALCULATED

VALUES.

NOTES: The following formulas are used to calculate proper calibration values for Sense Resistors other than

those recommended.

R

SENSE

=

the measured value of the sense resistor in ohms (0.001% accuracy).

I

Onom

=

Nominal (rated) current output of BOP in Amperes (e.g., for BOP 50-20M,

I = 20A)

A. 0V, Tolerance = ±(

R

SENSE) x (0.1) x (

I

Onom)-- result in mV.

B. (

R

SENSE) x (

I

Onom)--result in V, Tolerance = ±(

R

SENSE) x (0.1) x (

I

Onom)--result in mV.

B. (

R

SENSE) x (

I

Onom)--result in V, Tolerance = ±(

R

SENSE) x (0.5) x (

I

Onom)--result in mV.