4 how to access the menus, 1 overall menu structure, How to access the menus -6 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.2.01 to 2.37 User Manual

Page 66: Overall menu structure -6, R. 3.2.4)

background image

3-6

BOP HIPWR 022108

If the display is not viewable, press

#

twice. The display will cycle through the range of con-

trast settings. Press

#

again to lock in the preferred contrast.

To select between the meter (Figure 3-3) and time line (Figure 3-4) displays refer to PAR.
3.2.5.3. To change the default power-up settings, refer to PAR. 3.3.7.

3.2.4

HOW TO ACCESS THE MENUS

From the power-up screen, pressing the Function keys indicated on the LCD opens the associ-
ated menu. The menu opened may list submenus that may be opened either directly by press-
ing the associated Function keys, or by highlighting an item on the list and pressing the
View/Modify function key. Menus and submenus will display a list of parameters, with the top
one highlighted. The function key assignments can vary, but generally offer the following
choices:

!

allows the highlighted parameter to be viewed or modified. After changing the

parameter, the following choices are available.

$

- SAVE or

ENTER

to save the change

%

- EXIT to abort the change and exit to the previous menu.

@

- RESTORE DEFAULT restores factory defaults for the parameters displayed

(except for GPIB address). The factory defaults may be saved as power-up defaults by
pressing

$

.

#

- The function varies, depending on the menu. In most cases

#

is used to abort a

change without applying the modified setting. From the power-up screen

#

is used to

adjust contrast. In the Revisions/TEST submenu of the General Setup Menu,

#

is used

to execute a test.

$

- SAVE FOR POWER-UP Saves the configuration shown as a power-up setting so

the changes will not be lost when the unit is turned off.

%

- APPLY EXIT applies the current (changed) setting without saving for power-up and

exits to the previous menu or to the power-up screen, EXIT leaves the current menu
without saving or applying changes.

3.2.4.1

OVERALL MENU STRUCTURE

The menu structure is as follows (NOTE:

BOLD

= Factory Default):

Power-up Screen (Power up menu)

!

- Save/Recall

Saved Setups (Figure 3-8): Recall one of 99 saved setups.

Saved Setup Details (Table 3-8): Mode (voltage/current), main channel reference (internal/exter-
nal/external reference level) and setting, protection limit (internal/external/lesser limit) and setting(s),
output status (on/off)

@

- Waveform

Saved Waveforms (Figure 3-9): Choose one of 16 saved waveforms.

New Waveform Settings (Table 3-12): Name (max. 10 characters), protection settings, count, mode
(voltage/current)

Waveform Settings (Figure 3-10): Name, protection settings, count, segment list, mode

Segment Details (Table 3-11): Type (square/±ramp/triangle/sine/level), frequency or period, p-p
amplitude, offset, start/stop angle for sine and triangle, initial/repeat

#

- Display

Display and Beep Settings (Table 3-3): Display (meters/graphics (12 choices)), background (white/black),
contrast, beep (On/Off/Error only)