GW Instek GDS-1000A Series User Manual User Manual
Page 129

APPENDIX
129
Cursors and
Measurement
Voltage
Vpp, Vamp, Vavg, Vrms, Vhi, Vlo, Vmax,
Vmin, Rise Preshoot/ Overshoot, Fall
Preshoot/ Overshoot
Time
Freq, Period, Rise Time, Fall Time, +
Width, – Width, Duty Cycle
Delay
FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF
Cursors
Voltage difference (ΔV) and
Time difference (ΔT) between cursors
Auto Counter
Resolution: 6 digits, Accuracy: ±2%
Signal source: All available trigger source
except the Video trigger
Control Panel
Function
Autoset
Automatically adjust Vertical Volt/div,
Horizontal Time/div, and Trigger level
Save/Recall
Up to 15 sets of measurement
conditions and waveforms
Display
LCD
5.6 inch, TFT, brightness adjustable
Resolution (dots) 234 (Vertical) x 320 (Horizontal)
Graticule
8 x 10 divisions
Display
Contrast
Adjustable
Interface
USB Slave
Connector
USB1.1 & 2.0 full speed compatible
(flash disk not supported)
SD Card Slot
Image (BMP) and waveform data (CSV)
Probe
Compensation
Signal
Frequency range 1kHz ~ 100kHz adjustable, 1kHz step
Duty cycle
5% ~ 95% adjustable, 5% step
Amplitude
2Vpp±3%
Power Source
Line Voltage
100V~240V AC, 47Hz~63Hz
Power
Consumption
18W, 40VA maximum
Fuse Rating
1A slow, 250V
Operation
Environment
Ambient temperature 0 ~ 50°C
Relative humidity ≤ 80%, 40°C or below
≤ 45%, 41°C~50°C
Storage
Environment
Storage Temperature: -10°C~60°C, no condensation-
Relative humidity 93% @ 40°C
65% @ 41°C~60°C
Dimensions
310(W) x 142(H) x 140(D) mm
Weight
Approx. 2.5kg