beautypg.com

Index – Yokogawa Button Operated DX2000 User Manual

Page 86

background image

3-25

IM 04L41B01-62EN

1

2

3

4

5

Index

Detailed Information for

Attributes of Screens and Components

Attribute

Set value/choice

(Underlined items are initial

set values)

Description, conditions

Alarm level

[1], [2], [3], [4], [All]

The assigned alarm level is set.
All: This becomes ON when an alarm occurs for any one of Alarm

level 1 to 4.

Text indicating the alarm kind is not displayed.

Text showing the alarm kind is not displayed when Channel alarm is

OFF.

Color

[Red], [Orange], [Lime],

[Yellow], [Pink], [Black],

[White]

This is the color for display when no alarm has occurred.

Level 1

[Red], [Orange], [Lime],

[Yellow], [Pink], [Black],

[White], [ALARM]

This is the character color for display at the time of occurrence of a

level 1 alarm.
ALARM: This is the alarm display color set for each alarm level.

The alarm levels are [1] and [All].

Level 2

Same choice as for “level 1”

This is the character color for display at the time of occurrence of a

level 2 alarm.
ALARM: This is the alarm display color set for each alarm level.

The alarm levels are [2] and [All].

Level 3

Same choice as for “level 1”

This is the character color for display at the time of occurrence of a

level 3 alarm.
ALARM: This is the alarm display color set for each alarm level.

The alarm levels are [3] and [All].

Level 4

Same choice as for “level 1”

This is the character color for display at the time of occurrence of a

level 4 alarm.
ALARM: This is the alarm display color set for each alarm level.

The alarm levels are [4] and [All].

Alarm kind display

[Off], [On]

This selects display (On) / no display (Off) of strings that indicate

alarm kind.

Synchronize action

►Section 3.3

3.12 Attributes of Alarm Indicator Components